Fanimation FP8094GR - Manual de uso
Ventilador de techo Fanimation FP8094GR - Manual de uso, léela gratuitamente en línea en formato PDF. Esperamos que esto te ayude a resolver cualquier duda que puedas tener. Si tienes más preguntas, contáctanos a través del formulario de contacto.
How to Operate Your Ceiling Fan
16
Figure 1
Figure 2
Figure 4
Figure 5
MAIN FUSE BOX
For illustrative purposes only
-not
intended to cover all types of controls
2.
Restore electrical power to the outlet box by turning
the electricity on at the main fuse box. (Figure 2)
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
c o n n e c t o r s , e x c e p t f o r t h e g r o u n d w i r e . D o n o t
operate fan until the blades are in place. Noise and
fan damage could result.
WARNING
1.
IMPORTANT:
Using a full range dimmer switch
(not included) to control fan speed will damage the fan.
To reduce the risk of fire or electrical shock, do not use
a full range dimmer switch to control the fan speed.
(Figure 1)
WARNING
Do not operate this fan with a variable (Rheostat) wall
controller or dimmer switch. Doing so could result in
damage to the ceiling fan's remote control unit.
3.
To make fan operational, install 23A/12V battery
(included) in hand-held remote transmitter, with fan
power off. Then follow the remote code setting
process. (If not used for long periods of time, remove
battery toprevent damage to transmitter). Store the
remote away from excessive heat or humidly.
(Figure 3)
NOTE: The remote unit has 32 different code
combinations. To prevent possible interference from or
to other remote units, simply change the combination
code in the remote and receiver.
4.
To set the remote code with a small screwdriver or
ball point pen (neither included), slide dip switches
firmly up or down. (Figure 4)
NOTE: Factory setting is all up. Do not use this
position.
Dip Switch
ON DIP
1 2 3 4 5
Remote
12V 23A
Battery (1 pcs)
Figure 3
5.
Remote functions: (Figure 5)
,QGLFDWRU/('OLJKWIDQVSHHG
EXWWRQ7XUQVIDQRII
)DQ6SHHG
Turns fan on and turns speed up.
Turns fan on and turns speed down.
/LJKWEXWWRQ7XUQVOLJKWRQDQGRII
Increases light output level.
Decreases light output level.
Tap and the fan and light will turn off after
3 hours.
Tap and the fan and light will turn off after
6 hours.
Tap and the fan and light will turn off after
1 hour.
"Cargando la instrucción" significa que debes esperar hasta que el archivo se cargue y puedas leerlo en línea. Algunas instrucciones son muy grandes y el tiempo de carga depende de la velocidad de tu conexión a Internet.
Otros modelos de ventiladores de techo Fanimation
-
Fanimation FP4640BSLW
-
Fanimation FP6285BMW
-
Fanimation FP6721BBL-48BL
-
Fanimation FP6721BBL-48BL-LK
-
Fanimation FP6721BBL-48DWA
-
Fanimation FP6721BBL-48DWA-LK
-
Fanimation FP6721BBL-48N-LK
-
Fanimation FP6721BBL-48WE
-
Fanimation FP6721BBL-48WE-LK
-
Fanimation FP6721BBL-48WK