ricavate  maggiorando  la
fessura 

tra 

porta 

e

pavimento);

b) essere  situate  nella  parte

bassa 

di 

una 

parete

esterna, 

preferibilmente

opposta  a  quella  in  cui  si
trova  l’evacuazione  dei  gas
combusti;

c) la  loro  posizione  deve

essere  scelta  in  modo  tale
da  evitare  che  possano
essere 

ostruite 

e, 

se

praticate  sui  muri  esterni,
esse 

devono 

essere

protette  con  griglie,  reti
metalliche  ecc.  poste  sulla
faccia esterna del muro con
una sezione netta.

In  caso  nel  locale  sia  installato
un 

elettroventilatore 

per

l’evacuazione  dell’aria  viziata,
le aperture per il ricambio d’aria
devono garantire un passaggio
d’aria  di  almeno  35  m

3

/h  per

ogni kW di potenza installata in
ambiente.

ALLACCIAMENTO GAS

Il  forno  può  funzionare  a  gas
naturale (metano) a gas liquido
(GPL), e può essere facilmente
eseguita  la  conversione  da  un
tipo  all’altro  di  gas,  come
descritto nei successivi capitoli.
L’allacciamento  alla  rete  di
distribuzione 

deve 

essere

eseguito 

da 

personale

specializzato  e  secondo  le
prescrizioni  relative  alle  norme
UNI-CIG 7129, 7131.
Nel  caso  l’apparecchio  venga
alimentato  con  gas  liquido
(GPL) in bombola, deve essere
utilizzato  un  regolatore  di
pressione conforme alla norma
UNI CIG 7432.

ALLACCIAMENTO DEL
TUBO METALLICO

L’allacciamento 

gas 

può

essere  eseguito  mediante  un
tubo  metallico  rigido  conforme
alla  norma  UNI  8863  fissato
saldamente  al  raccordo  “G”
(Fig.  3),  oppure,  mediante  un
tubo  flessibile  di  acciaio
inossidabile  a  parete  continua,
di cui alla norma UNI CIG 9891
con lunghezza max. 2 mt.
Il raccordo “G” e la guarnizione

gap  between  the  bottom  of
doors and the floor);

b) situated  at  the  bottom  of  an

external  wall,  preferably
opposite  the  wall  on  which
combustion  products  are
extracted ;

c) the 

positions 

of 

the

apertures  should  selected
so as to avoid the possibility
of  their  being  obstructed
and,  if  made  in  external
walls, 

they 

must 

be

protected  with  grilles,  metal
meshes,  etc.  installed  on
the outside face of the wall.

If  an  electric  extractor  fan  for
the  removal  of  foul  air  is
installed  in  the  room,  the
apertures  provided  for  air
changes 

must 

allow 

a

ventilation  rate  of  at  least  35
m

3

/h per kW of power installed.

GAS CONNECTION

The  oven  is  designed  to
operate  with  both  natural  gas
(methane)  and  liquid  gas
(LPG),  and  can  be  easily
converted  from  one  type  to
another 

following 

the

instructions  given  in  the  relative
section 

of 

this 

booklet.

Connection  to  the  gas  supply
must be carried out by qualified
technicians and in conformance
with the requirements.
If  the  appliance  is  to  operate
with  gas  bottles  (LPG),  a
pressure  regulator  conforming
to the requirements.

RIGID PIPE
CONNECTION

Connection  to  the  mains  gas
supply may be made via a rigid
pipe  firmly  attached  to  the
fitting  “G”  (Fig.  3),  or  via  a
flexible 

stainless 

steel

continuous-wall 

hose,

conforming  with  a  maximum
length of 2 metres.
The fitting “G” and seal “C” are
supplied  with  the  appliance,
and comply with standards.

de  préférence  opposée  à
celle dans laquelle se trouve
l’évacuation des gaz brûlés;

c) leur position doit être choisie

de  façon  à  éviter  qu’elles
soient  obstruées  et,  si
pratiquées  sur  des  murs
externes,  elles  doivent  être
protégées  avec  des  grilles,
des  réseaux  métalliques
etc.  placés  sur  la  façade
externe  du  mur  avec  une
section nette.

Si  le  local  est  équipé  d’un
électroventilateur  d’évacuation
de  l’air  vicié,  les  ouvertures  de
changement 

d’air 

doivent

garantir  un  passage  d’air  d’au
moins  35  m

3

/h  par  kW  de

puissance  installée  dans  le
local.

BRANCHEMENT DU GAZ

Le four peut fonctionner au gaz
naturel  (méthane)  ou  liquide
(GPL).  La  conversion  d’un  gaz
à  l’autre  est  facile,  comme
expliqué  dans  les  pages
suivantes.  Le  branchement  au
réseau  de  distribution  doit  être
fait 

par 

une 

personne

compétente  dans  le  respect
des normes.
Si  l’appareil  est  alimenté  en
gaz  liquide  (GPL)  en  bouteille,
utiliser  un  régulateur  de
pression conforme à la norme.

BRANCHEMENT  DU  TUBE
MÉTALLIQUE

Le  branchement  du  gaz  doit
être 

effectué 

par 

tube

métallique 

rigide 

fixé

solidement au raccord “G” (Fig.
3)  ou  par  flexible  acier  inox  à
mur  continu,  d’une  longueur
max. 2 mètres.
Le  raccord  “G”  et  le  joint
d’étanchéité  “C”  sont  fournis
comme 

accessoires 

avec

l’appareil  et  sont  conformes

8

instruccionespdf.com
¿Tiene más preguntas?

¿No ha encontrado la solución a su problema en el manual o tiene otros problemas? Haga su pregunta en el siguiente formulario con una descripción detallada de su situación para que otras personas y expertos puedan responderla. Si sabe cómo resolver el problema de otra persona, ayúdele :)

Hacer una pregunta