IT
GB
FR
ISTRUZIONI PER
L’INSTALLATORE
NORME PER L’INSTALLAZIONE
DELL’APPARECCHIO
(ubicazione e ventilazione lo-
cale)
Le norme italiane che regolano
l’installazione, la manutenzione
e
la
conduzione
degli
apparecchi a gas per uso
domestico sono le seguenti:
- UNI-CIG n. 7129
- UNI-CIG n. 7131
Riportiamo di seguito uno
stralcio di tali norme. Per tutte
le indicazioni non riportate è
necessario consultare le norme
citate.
UBICAZIONE:
(Fig. 2) gli apparecchi di cottura
devono sempre scaricare i
prodotti della combustione in
apposite cappe, che devono
essere collegate a camini,
canne fumarie o direttamente
all’esterno.
In caso non esista la possibilità
di applicazione della cappa, è
consentito l’impiego di un
elettroventilatore, installato su
finestra o su parete affacciata
sull’esterno, da mettere in
funzione contemporaneamente
all’apparecchio, purché siano
tassativamente rispettate le
norme inerenti la ventilazione.
VENTILAZIONE DEL
LOCALE:
(Fig. 2) è indispensabile che
nel locale in cui sono installati
degli apparecchi a gas possa
almeno affluire tanta aria
comburente quanta ne viene
richiesta dalla combustione del
gas consumato dai vari
apparecchi.
È quindi necessario, per
l’afflusso dell’aria nel locale,
praticare delle aperture che
rispondano
ai
requisiti
seguenti:
a) avere una sezione libera
totale di 6 cm
2
per ogni kW
con un minimo di 100 cm
2
(tali
aperture
possono
eventualmente
essere
Fig. 2 - Abb. 2 - Afb. 2
INSTRUCTIONS FOR
THE INSTALLER
INSTRUCTIONS FOR
INSTALLATION OF THE
APPLIANCE (positioning and
ventilation requirements)
The regulations covering the
installation, maintenance and
operation of gas appliances for
domestic use are applicable
regulations.
An extract of these regulations
appears
below.
For
all
indications not covered, refer to
the
above-mentioned
regulations.
POSITIONING:
(Fig. 2) the products of
combustion
from
cooking
appliances must always be
discharged
into
suitable
extractor hoods, which must be
connected to a chimney, flue or
vented directly to outside the
building. In situations where it
is not possible to install an
extractor hood, an electric
extractor fan installed in a
window or external wall may be
used,
provided
that
all
requirements of the ventilation
regulations are satisfied; the
fan should switch on whenever
the appliance is in operation.
VENTILATION:
(Fig. 2) it is essential that the
room in which gas appliances
are installed is adequately
ventilated to ensure that all the
appliances receive the required
quantity of fresh air for
combustion.
To ensure an adequate air
flow, it may be necessary to
create apertures in accordance
with
the
following
requirements:
a) with cross-sectional area of
6 cm
2
per kW with a
minimum
cross-sectional
area of 100 cm
2
(these
apertures may also be
created by increasing the
INSTRUCTIONS POUR
L’INSTALLATEUR
NORMES
D’INSTALLATION
DE L’APPAREIL
(emplacement et ventilation
locale)
Les
normes
d’installation,
d’entretien et de conduite des
appareils à gaz à usage
domestique sont les normes
en viguer.
Vous trouverez ci-dessous un
aperçu de ces textes. Pour
toutes les indications non
reportées consulter les textes
de référence.
EMPLACEMENT
(Fig. 2) Les appareils de
cuisson
doivent
toujours
évacuer les produits de
combustion dans des hottes ad
hoc, qui doivent être reliées à
des carneaux de fumées ou
directement à l’extérieur. En
cas d’impossibilité d’installation
de la hotte, utiliser un
électroventilateur installé sur la
fenêtre ou sur un mur orienté
vers l’extérieur, à démarrer
simultanément avec l’appareil,
à condition de respecter
impérativement les normes de
ventilation.
VENTILATION DU LOCAL
(Fig. 2) Il est indispensable que
le local d’installation des
appareils à gaz soit aéré en
quantité d’air suffisante pour la
combustion des gaz.
Il est donc indispensable de
pratiquer des ouvertures ad
hoc
qui
présentent
les
caractéristiques suivantes:
a) avoir une section libre totale
de 6 cm
2
par kW avec un
minimum de 100 cm
2
(ces
ouvertures peuvent être
pratiquées en majorant les
ouvertures entre porte et
sol);
b) être situées dans la partie
basse d’une paroi externe,
6
¿Tiene más preguntas?¿No ha encontrado la solución a su problema en el manual o tiene otros problemas? Haga su pregunta en el siguiente formulario con una descripción detallada de su situación para que otras personas y expertos puedan responderla. Si sabe cómo resolver el problema de otra persona, ayúdele :)